Wholesales CZCL A-300AB-5 LED Display Slim Power Supply 5V 60A 300W
Specification
|
Model |
A-300AB-5 |
||||||
|
Output
|
DC voltage |
5V |
|||||
|
Rated current |
60A |
||||||
|
Current range |
0~60A |
||||||
|
Rated power |
300W |
||||||
|
Ripple & Noise |
200mVp-p |
||||||
|
Tage regulation ran |
4.5~5.5V |
||||||
|
Voltage accuracy |
±2.0% |
||||||
|
Line adjustment rate |
±0.5% |
||||||
|
Load adjustment rate |
±2% |
||||||
|
Rise |
3000ms,50ms/230VAC 100% load |
||||||
|
Hold up time (Typ) |
20ms/230VAC 100% load |
||||||
|
Input
|
Voltage range |
180~264VAC |
|||||
|
Frenquency range |
47~63HZ |
||||||
|
PFC (Typ) |
PF≥0.5 |
||||||
|
Efficiency(Typ) |
≥86% |
||||||
|
Alternating |
15VAC |
/ |
|||||
|
|
30VAC |
3.1A |
|||||
|
Rush current (Typ) |
60A/230VAC |
||||||
|
Leakage current |
<1mA/230VAC |
||||||
|
Protection
|
Over load |
110~150% rated | |||||
|
Short circuit |
shut off, AC recycle to re-start | ||||||
|
Over voltage |
voltage limited 110%~140% of rated voltage | ||||||
|
Over temp. |
/ |
||||||
|
Environment
|
Working temp. |
-20℃~+50℃ (AC 230V) (Refer to temperature derating curve) | |||||
|
Working humidity |
20~90%RH no condensing | ||||||
|
Storage Temp. |
-30~+85℃ | ||||||
|
Storage humidity |
10~95%RH no condensing | ||||||
|
Temp. coefficiency |
±0.03%/℃ (0~50℃) | ||||||
|
Vibration resistance |
10~500Hz,2G,10min/cycle,X、Y、Z 60min in each direction | ||||||
|
Safety Standards |
Design refer to GB4943,UL60950-1,EN60950-1 | ||||||
|
Withstand voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||||
|
solation resistance |
I/P-O/P、I/P-FG、O/P-FG:>50MΩ/500VDC/25℃/70%RH | ||||||
|
EMC |
Design refer to GB9254 EN55022,Class A | ||||||
|
Harmonic Current |
Design refer to GB17625.1;EN61000-3-2,-3 | ||||||
|
EMS |
Design refer to EN55024 ;EN61000-4-2,3,4,5,6,8,11 | ||||||
|
Others
|
Lifetime |
100,000 hours (25℃) | |||||
|
Size |
212*81.5*31.1 (L*W*H) | ||||||
|
package |
0.55Kg/pcs | ||||||
|
Remarks |
*In order to extend the lifetime, it is recommended to configure the load no more than 30% of the remaining allowance. For example : the power of the device requires 100W, then use the power of less than 130W.*Ripple test method : 20MHz oscilloscope in power output terminal test, oscilloscope probe wire length is not more than 12mm, and input parallel 47uF electrolytic capacitors and 0.1uF high frequency capacitance probe. | ||||||
Load Temperature Derating Curve
Installation Drawing
|
Pin No |
Assignment |
Pin No |
Assignment |
|
1~2 |
AC/N |
6~8 |
DC output(-V) |
|
3~4 |
AC/L |
9~11 |
DC output(+V) |
|
5 |
FG |
|