Huidu W04 Single Color Wi-Fi LED Display Control Card Cost-effective Card for Door Bar Screen, Store Sign Screen
Connection Diagram
After the Wi-Fi control card is powered on, cell phones and laptops can connect to the control card's Wi-Fi hotspot for debugging or updating programs.
Function List
| Content | Function description |
| Control range | Single color:768* 64, Max Width:1536 Max Height:64;Dual color:384*64 |
| FLASH Capacity | 1M Byte(Practical usage 512KB) |
| Communication | Wi-Fi |
| Program Quantity | Max 1000pcs Programs. Support play by time section or control by buttons. |
| Area Quantity | 20 areas with separate zone, and separated special effects and border |
| Display Showing | Text, Time, Temperature (temperature and humidity), Timekeeping, Count, Lunar calendar |
| Display | Sequence display, button switch |
| Clock Function | 1,Support Digital Clock/ Dial Clock / Lunar Time/
2,The font, size, color and position can be set freely 3,Support multiple time zones |
| Expandable Devices | Temperature, humidity and light sensors |
| Automatic Switch Screen | Support timer switch machine |
|
Dimming |
Supports three brightness adjustment modes: manual adjustment, automatic
adjustment, adjustment by time period |
| Working Power | 3W |
Port Definition
Dimensions
Interface Description
| Serial number | Name | Description |
| 1 | Power supply input | Connect to a 5V DC power supply |
| 2 | S1 | click to switch screen test status |
| 3 | P5 | Connect the temperature/ humidity sensor |
| 4 | HUB ports | 4 HUB12,For connecting to the display |
| 5 | P7 | Connected to a brightness sensor to automatically adjust the brightness of the LED display |
Basic Parameters
| Parameter Term | Parameter Value |
| Work voltage(V) | DC 4.2V-5.5V |
| Work temperature(℃) | -40℃~80℃ |
| Work humidity(RH) | 0~95%RH |
| Storage
temperature(℃) |
-40℃~105℃ |
Precaution:
1) To ensure that the control card is stored during normal operation, make sure the battery on the control card is not loose;